In general, the concrete pump must comply with the following safety device inspection regulations during the installation process. Specifically, there are the following points:

1. The hydraulic system should be equipped with safety devices to prevent overload and hydraulic shock. The adjustment pressure of the safety relief valve should not exceed 110% of the rated working pressure of the system. The rated working pressure of the system should not be greater than the rated pressure of the hydraulic pump.

2. The concrete pump brake should be sensitive, reliable, effective, and not biased; the embossing and printing should meet the inspection requirements, and the free pedal of the brake pedal should meet the requirements of the instruction manual.

3. The concrete pump alarm device and emergency brake switch should work reliably.

4. The concrete pump walkway and protective railings should be complete and intact. The safety warning signs and related operation signs should be complete and eye-catching. The operation room should be equipped with fire-fighting equipment.